Output
Output Power Capacity
660 Watts / 1100 VA
Max Configurable Power
660 Watts / 1100 VA
Nominal Output Voltage
230V
Efficiency at Full Load
97.0%
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Topology
Line Interactive
Waveform Type
Stepped approximation to a sinewave
Output Connections
(6) IEC 320 C13 (Battery Backup) | |
(2) IEC Jumpers (Battery Backup) |
Efficiency at Half Load
95.0%
Input
Nominal Input Voltage
230V
Input Frequency
50/60 Hz +/- 3 Hz (auto sensing)
Input Connections
IEC-320 C14 |
Cord Length
1.16 meters
Input voltage range for main operations
150 - 280V
Maximum Input Current
5A
Input Breaker Capacity
10 A
Batteries & Runtime
Battery Type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical recharge time
8 hour(s)
Replacement Battery
(Service center technician only)
APCRBC113
RBC™ Quantity
1
Runtime Graph
Communications & Management
Control panel
LED Status display with On Line : On Battery
Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Surge Protection and Filtering
Surge energy rating
273 Joules
Data Line Protection
--
Physical
Maximum Height
215.00 mm
Maximum Width
130.00 mm
Maximum Depth
336.00 mm
Net Weight
12.00 KG
Shipping Weight
12.92 KG
Shipping Height
295.00 mm
Shipping Width
245.00 mm
Shipping Depth
440.00 mm
Master Carton Units
1.00
Color
Black
SCC Codes
0073130429134 3
Units per Pallet
24.00
Environmental
Operating Environment
0 - 40 °C
Operating Relative Humidity
0 - 95%
Operating Elevation
0-3000 meters
Storage Temperature
-15 - 40 °C
Storage Relative Humidity
0 - 95%
Storage Elevation
0-9000 meters
Audible noise at 1 meter from surface of unit
45.00 dBA
Conformance
Regulatory Approvals
CE, EN/IEC 60950-1, GOST, NEMKO
Standard Warranty
2 years repair or replace
Sustainable Offer Status
RoHS
Compliant
REACH
REACH: Contains No SVHCs
Bộ lưu điện UPS APC BX1100CI
BX1100CI Features
Automatic Voltage Regulation (AVR)
Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.
Overload protection
Safeguards unit from damage by automatically turning it off in the event of a short circuit or overload.
Replace Battery LED
An external Replace Battery LED informs the end-user that the battery needs to be replaced.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Cold-start capable
Provides temporary battery power when the utility power is out.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Back-UPS Features & Benefits
Protection
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Availability
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Serviceability
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
Manageability
Audible alarms
Provides notification of changing utility power and UPS power conditions
LED status display
Quickly understand unit and power status with visual indicators.
Safety
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.